Used Sterlco Model: 96 kW (48 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit
1 / 11Questions? Call (847) 360-9170 and mention DCM-1952.
| Status | Sold |
|---|---|
| Manufacturer | Sterlco |
| Size | 96 kW (48 kW per zone) |
| Inventory Number | DCM-1952 |
Sterlco - 96 kW (48 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit, Controls
Features & Accessories
- Heating Capacity Zone #1: 48 KW - Heating Capacity Zone #2: 48 KW - Total Heating Capacity: 96 KW
- Alarms for low fluid pressure, pump rotation, over temperature
- Set points for Process, High Alarm, Low Alarm
- Displays for Process Temperature, Return Temperature and Temperature Difference
Item Specifications for DCM-1952
| US | Metric | |
| Full Load Amps @ 460/3/60: | 61 | 61 |
| Main Heater Power (Zone #1): | 48 KW | 48 KW |
| Main Heater Power (Zone #2): | 48 KW | 48 KW |
| Maximum Operating Temperature: | 550 degrees F | 288 Degrees C |
| Reservoir Capacity: | 17 Gallons | 64 Liters |
| Pump Motor Size (Zone #1): | 3 HP | 2.2 KW |
| Pump Motor Size (Zone #2): | 3 HP | 2.2 KW |
| Flow Rate (Zone #1): | 50 gallons per minute | 189 liters per gallon |
| Flow Rate (Zone #2): | 50 gallons per minute | 189 liters per gallon |
| Connection size/type: | 1.5 inches | 38 mm |
| Overall Size (H x W x D): | 62 x 48 x 42 inches | 1574 x 1219 x 1066 mm |
Video
Description
Used, Sterlco Model 96 kW (48 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit For Sale, Features include: Alarms for low fluid pressure, pump rotation, over temperature, Set points for Process, High Alarm, Low Alarm, Displays for Process Temperature, Return Temperature and Temperature Difference, Controls, Second Hand, DCM-1952
PURCHASER'S (Buyer's) RESPONSIBILITY AND INDEMNITY: Used machines, equipment or any part thereof, may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It shall be a Purchaser's (Buyer's) responsibility to ensure that any and all merchandise or equipment purchased from Die Cast Machinery, LLC or its affiliates is installed and operated in a proper and safe manner. Purchaser (Buyer) also acknowledges that it may have to install or change guards, safeties, warnings or other components to ensure that the merchandise or machines purchased will conform to all laws, codes, regulations, ordinances, statutes, insurance requirements and industry standards. Purchaser agrees to defend, indemnify and hold harmless Die Cast Machinery, LLC from and against all suits, claims, costs, damages and expenses, including, but not limited to, reasonable attorneys' fees, arising out of, or in connection with, the transportation, purchase, ownership, or use of the merchandise or equipment sold hereunder. Information has been obtained from sources deemed reliable, buyers should avail themselves of the opportunity to inspect the items before purchase.
Compare DCM-1952 with Similar Machines
| DCM-1952 (this machine) | DCM-6326 | DCM-6056 | DCM-6317 | |
|---|---|---|---|---|
| Brand | Sterlco | Mokon | Regloplas | Robamat |
| Model | — | H54224TW01 | 301DG/24/FM65/1K/RT45 | 5212 |
| Size | 96 kW (48 kW per zone) | 48 kW (24 kw per zone) | 48 KW (24 kw per zone) | 40 kW (20 kw per zone) |
| Controls | — | Eurotherm 3216 | RT45 | Thermocast |
| Full Load Amps @ 460/3/60 | 61 | 67.00 amp | — | — |
| Main Heater Power (Zone #1) | 48 KW | 24 KW | 24 kW | — |
| Main Heater Power (Zone #2) | 48 KW | 24 KW | 24 kW | — |
| Maximum Operating Temperature | 550 degrees F | 500 degrees F | 570 degrees F | — |
| Pump Motor Size (Zone #1) | 3 HP | 2 HP | 3.8 HP | — |
| Pump Motor Size (Zone #2) | 3 HP | 2 HP | 3.8 HP | — |
| View Details | View Details | View Details |
Frequently Asked Questions about DCM-1952
What size is the Sterlco (DCM-1952)?
The Sterlco is 96 kW (48 kW per zone).
What are the motor and power details?
- Main Heater Power (Zone #1): 48 KW (48 KW)
- Main Heater Power (Zone #2): 48 KW (48 KW)
- Pump Motor Size (Zone #1): 3 HP (2.2 KW)
- Pump Motor Size (Zone #2): 3 HP (2.2 KW)
How big and heavy is it for rigging and shipping?
- Overall Size (H x W x D): 62 x 48 x 42 inches (1574 x 1219 x 1066 mm)
What features and accessories come with DCM-1952?
- Alarms for low fluid pressure, pump rotation, over temperature
- Set points for Process, High Alarm, Low Alarm
- Displays for Process Temperature, Return Temperature and Temperature Difference
Is there a video of this machine?
Yes. Use the Play Video button beside the photos.
Is there a printable spec sheet?
Yes. Use the Print PDF button beside the photos for a printable spec sheet of DCM-1952.
Can I inspect the machine before buying?
Yes. Buyers should take the opportunity to inspect the items before purchase.
Is DCM-1952 still available?
No, DCM-1952 has been sold. See the available Hot Oil Units, or call (847) 360-9170 and mention DCM-1952.