Used Sterlco Model: 96 kW (48 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit

Questions? Call (847) 360-9170 and mention DCM-1952.

StatusSold
ManufacturerSterlco
Size96 kW (48 kW per zone)
Inventory NumberDCM-1952

Sterlco - 96 kW (48 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit, Controls

View Available Hot Oil Units

Features & Accessories

  • Heating Capacity Zone #1: 48 KW - Heating Capacity Zone #2: 48 KW - Total Heating Capacity: 96 KW
  • Alarms for low fluid pressure, pump rotation, over temperature
  • Set points for Process, High Alarm, Low Alarm
  • Displays for Process Temperature, Return Temperature and Temperature Difference

Item Specifications for DCM-1952

USMetric
Full Load Amps @ 460/3/60:6161
Main Heater Power (Zone #1):48 KW48 KW
Main Heater Power (Zone #2):48 KW48 KW
Maximum Operating Temperature:550 degrees F288 Degrees C
Reservoir Capacity:17 Gallons64 Liters
Pump Motor Size (Zone #1):3 HP2.2 KW
Pump Motor Size (Zone #2):3 HP2.2 KW
Flow Rate (Zone #1):50 gallons per minute189 liters per gallon
Flow Rate (Zone #2):50 gallons per minute189 liters per gallon
Connection size/type:1.5 inches38 mm
Overall Size (H x W x D):62 x 48 x 42 inches1574 x 1219 x 1066 mm

Video

Description

Used, Sterlco Model 96 kW (48 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit For Sale, Features include: Alarms for low fluid pressure, pump rotation, over temperature, Set points for Process, High Alarm, Low Alarm, Displays for Process Temperature, Return Temperature and Temperature Difference, Controls, Second Hand, DCM-1952

PURCHASER'S (Buyer's) RESPONSIBILITY AND INDEMNITY: Used machines, equipment or any part thereof, may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It shall be a Purchaser's (Buyer's) responsibility to ensure that any and all merchandise or equipment purchased from Die Cast Machinery, LLC or its affiliates is installed and operated in a proper and safe manner. Purchaser (Buyer) also acknowledges that it may have to install or change guards, safeties, warnings or other components to ensure that the merchandise or machines purchased will conform to all laws, codes, regulations, ordinances, statutes, insurance requirements and industry standards. Purchaser agrees to defend, indemnify and hold harmless Die Cast Machinery, LLC from and against all suits, claims, costs, damages and expenses, including, but not limited to, reasonable attorneys' fees, arising out of, or in connection with, the transportation, purchase, ownership, or use of the merchandise or equipment sold hereunder. Information has been obtained from sources deemed reliable, buyers should avail themselves of the opportunity to inspect the items before purchase.

Compare DCM-1952 with Similar Machines

DCM-1952 (this machine)DCM-6326DCM-6056DCM-6317
BrandSterlcoMokonRegloplasRobamat
Model—H54224TW01301DG/24/FM65/1K/RT455212
Size96 kW (48 kW per zone)48 kW (24 kw per zone)48 KW (24 kw per zone)40 kW (20 kw per zone)
Controls—Eurotherm 3216RT45Thermocast
Full Load Amps @ 460/3/606167.00 amp——
Main Heater Power (Zone #1)48 KW24 KW24 kW—
Main Heater Power (Zone #2)48 KW24 KW24 kW—
Maximum Operating Temperature550 degrees F500 degrees F570 degrees F—
Pump Motor Size (Zone #1)3 HP2 HP3.8 HP—
Pump Motor Size (Zone #2)3 HP2 HP3.8 HP—
View DetailsView DetailsView Details

Frequently Asked Questions about DCM-1952

What size is the Sterlco (DCM-1952)?

The Sterlco is 96 kW (48 kW per zone).

What are the motor and power details?
  • Main Heater Power (Zone #1): 48 KW (48 KW)
  • Main Heater Power (Zone #2): 48 KW (48 KW)
  • Pump Motor Size (Zone #1): 3 HP (2.2 KW)
  • Pump Motor Size (Zone #2): 3 HP (2.2 KW)
How big and heavy is it for rigging and shipping?
  • Overall Size (H x W x D): 62 x 48 x 42 inches (1574 x 1219 x 1066 mm)
What features and accessories come with DCM-1952?
  • Alarms for low fluid pressure, pump rotation, over temperature
  • Set points for Process, High Alarm, Low Alarm
  • Displays for Process Temperature, Return Temperature and Temperature Difference
Is there a video of this machine?

Yes. Use the Play Video button beside the photos.

Is there a printable spec sheet?

Yes. Use the Print PDF button beside the photos for a printable spec sheet of DCM-1952.

Can I inspect the machine before buying?

Yes. Buyers should take the opportunity to inspect the items before purchase.

Is DCM-1952 still available?

No, DCM-1952 has been sold. See the available Hot Oil Units, or call (847) 360-9170 and mention DCM-1952.

Available Hot Oil Units

See all Hot Oil Units ›