Used Mokon Model: H44112Z6 12 kW (6 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit
1 / 12Questions? Call (847) 360-9170 and mention DCM-3552.
| Status | Sold |
|---|---|
| Manufacturer | Mokon |
| Model | H44112Z6 |
| Size | 12 kW (6 kW per zone) |
| Inventory Number | DCM-3552 |
Mokon - H44112Z6 12 kW (6 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit, Controls
Features & Accessories
- Total: 12kw
- Water Cooling Circuit
- HTF 500 Series Mokon Dependability
- Unit on casters for easy movement
- Built-in pump pressure relief valve
- Eurotherm Controls
Item Specifications for DCM-3552
| US | Metric | |
| Main Heater Power (Zone #1): | 6 KW | 6 KW |
| Pump Motor Size (Zone #1): | 1 HP | .75 KW |
| Flow Rate (Zone #1): | 10 gallons per minute | 37.8 liters per minute |
| Connection size/type (Zone #1): | .75 inch NPT | 19.05 mm NPT |
| Main Heater Power (Zone #2): | 6 KW | 6 KW |
| Pump Motor Size (Zone #2): | 1 HP | .75 KW |
| Flow Rate (Zone #2): | 10 gallons per minute | 37.8 liters per minute |
| Connection size/type (Zone #2): | .75 inch NPT | 19.05 mm NPT |
| Maximum Operating Temperature: | 500 degrees F | 260 degrees C |
| Overall Size (L x W x H): | 41 x 30 x 51 inches | 1041 x 762 x 1295 mm |
| Full Load Amps @ 460/3/60: | 17.94 amp | 17.94 amp |
Video
Description
Used, Mokon Model H44112Z6 12 kW (6 kW per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit For Sale, Features include: Water Cooling Circuit, HTF 500 Series Mokon Dependability, Unit on casters for easy movement, Built-in pump pressure relief valve, Eurotherm Controls, Controls, Second Hand, DCM-3552
PURCHASER'S (Buyer's) RESPONSIBILITY AND INDEMNITY: Used machines, equipment or any part thereof, may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It shall be a Purchaser's (Buyer's) responsibility to ensure that any and all merchandise or equipment purchased from Die Cast Machinery, LLC or its affiliates is installed and operated in a proper and safe manner. Purchaser (Buyer) also acknowledges that it may have to install or change guards, safeties, warnings or other components to ensure that the merchandise or machines purchased will conform to all laws, codes, regulations, ordinances, statutes, insurance requirements and industry standards. Purchaser agrees to defend, indemnify and hold harmless Die Cast Machinery, LLC from and against all suits, claims, costs, damages and expenses, including, but not limited to, reasonable attorneys' fees, arising out of, or in connection with, the transportation, purchase, ownership, or use of the merchandise or equipment sold hereunder. Information has been obtained from sources deemed reliable, buyers should avail themselves of the opportunity to inspect the items before purchase.
Compare DCM-3552 with Similar Machines
| DCM-3552 (this machine) | DCM-5890 | DCM-5657 | DCM-4700 | |
|---|---|---|---|---|
| Brand | Mokon | Delta T Systems | Delta T Systems | QPC |
| Model | H44112Z6 | T1221MS | T1221MS | H0-1210X-12 |
| Size | 12 kW (6 kW per zone) | 12 KW | 12 KW | 12 KW |
| Controls | — | Omron E5EN | Microprocessor-based PID Controller | Fenwal 921 |
| Main Heater Power (Zone #1) | 6 KW | 12 KW | 12 KW | 12KW |
| Pump Motor Size (Zone #1) | 1 HP | 1 HP | 1 HP | 1 HP @ 1,725 RPM |
| Flow Rate (Zone #1) | 10 gallons per minute | 10 Gallong Per Minute (GPM) | 10 Gallong Per Minute (GPM) | — |
| Connection size/type (Zone #1) | .75 inch NPT | — | — | 1 NPT |
| Maximum Operating Temperature | 500 degrees F | 550 degrees F | 550 degrees F | 450 Fahrenheit |
| Overall Size (L x W x H) | 41 x 30 x 51 inches | — | — | 36 x 24 x 52 inches |
| View Details | View Details | View Details |
Frequently Asked Questions about DCM-3552
What size is the Mokon H44112Z6 (DCM-3552)?
The Mokon H44112Z6 is 12 kW (6 kW per zone).
What are the motor and power details?
- Main Heater Power (Zone #1): 6 KW (6 KW)
- Pump Motor Size (Zone #1): 1 HP (.75 KW)
- Main Heater Power (Zone #2): 6 KW (6 KW)
- Pump Motor Size (Zone #2): 1 HP (.75 KW)
How big and heavy is it for rigging and shipping?
- Overall Size (L x W x H): 41 x 30 x 51 inches (1041 x 762 x 1295 mm)
What features and accessories come with DCM-3552?
- Water Cooling Circuit
- HTF 500 Series Mokon Dependability
- Unit on casters for easy movement
- Built-in pump pressure relief valve
- Eurotherm Controls
Is there a video of this machine?
Yes. Use the Play Video button beside the photos.
Is there a printable spec sheet?
Yes. Use the Print PDF button beside the photos for a printable spec sheet of DCM-3552.
Can I inspect the machine before buying?
Yes. Buyers should take the opportunity to inspect the items before purchase.
Is DCM-3552 still available?
No, DCM-3552 has been sold. See the available Hot Oil Units, or call (847) 360-9170 and mention DCM-3552.