SOLD

Used Sterlco Model: M2B9026-J1 96 kw (48 kw per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit

Questions? Call (847) 360-9170 and mention DCM-5533.

StatusSold
ManufacturerSterlco
ModelM2B9026-J1
Size96 kw (48 kw per zone)
Inventory NumberDCM-5533

Sterlco - M2B9026-J1 96 kw (48 kw per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit, Sterling M2B Controller Controls

View Available Hot Oil Units

Features & Accessories

  • Sterling Hot Oil Process Heater Temperature Control Unit with Sterlco M2B Controllers
  • Alarms for low fluid pressure, pump rotation, over temperature
  • Set points for Process, High Alarm, Low Alarm
  • Displays for Process Temperature, Return Temperature and Temperature Difference

Item Specifications for DCM-5533

USMetric
Main Heater Power Zone #1:48 KW48 KW
Pump Motor Size Zone #1:3 HP2.25 kw
Flow Rate Zone #1:71-90 gallons per minute265-341 liters per minute
Main Heater Power Zone #2:48 KW48 KW
Pump Motor Size Zone #2:3 HP2.25 kw
Flow Rate Zone #2:71-90 gallons per minute265-341 liters per minute
Process Connection Size/Type:2 inch NPT2 inch NPT
Maximum Operating Temperature:500 degrees F260 degrees C
Overall Size (L x W x H):41 x 20 x 47 inches1041 x 508 x 1193 mm
Power:126 Amps @ 460/3/60126 Amps @ 460/3/60
Approximate Shipping Weight:2,000 lbs909 kg

Video

Description

Used, Sterlco Model M2B9026-J1 96 kw (48 kw per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit For Sale, Features include: Sterling Hot Oil Process Heater Temperature Control Unit with Sterlco M2B Controllers, Alarms for low fluid pressure, pump rotation, over temperature, Set points for Process, High Alarm, Low Alarm, Displays for Process Temperature, Return Temperature and Temperature Difference, Sterling M2B Controller Controls, Second Hand, DCM-5533

PURCHASER'S (Buyer's) RESPONSIBILITY AND INDEMNITY: Used machines, equipment or any part thereof, may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It shall be a Purchaser's (Buyer's) responsibility to ensure that any and all merchandise or equipment purchased from Die Cast Machinery, LLC or its affiliates is installed and operated in a proper and safe manner. Purchaser (Buyer) also acknowledges that it may have to install or change guards, safeties, warnings or other components to ensure that the merchandise or machines purchased will conform to all laws, codes, regulations, ordinances, statutes, insurance requirements and industry standards. Purchaser agrees to defend, indemnify and hold harmless Die Cast Machinery, LLC from and against all suits, claims, costs, damages and expenses, including, but not limited to, reasonable attorneys' fees, arising out of, or in connection with, the transportation, purchase, ownership, or use of the merchandise or equipment sold hereunder. Information has been obtained from sources deemed reliable, buyers should avail themselves of the opportunity to inspect the items before purchase.

Compare DCM-5533 with Similar Machines

DCM-5533 (this machine)DCM-6326DCM-6056DCM-6317
BrandSterlcoMokonRegloplasRobamat
ModelM2B9026-J1H54224TW01301DG/24/FM65/1K/RT455212
Size96 kw (48 kw per zone)48 kW (24 kw per zone)48 KW (24 kw per zone)40 kW (20 kw per zone)
ControlsSterling M2B ControllerEurotherm 3216RT45Thermocast
Main Heater Power Zone #148 KW24 KW24 kW—
Pump Motor Size Zone #13 HP2 HP3.8 HP—
Flow Rate Zone #171-90 gallons per minute20 gallons per minute23 gallons per minute—
Main Heater Power Zone #248 KW24 KW24 kW—
Pump Motor Size Zone #23 HP2 HP3.8 HP—
Flow Rate Zone #271-90 gallons per minute20 gallons per minute23 gallons per minute—
View DetailsView DetailsView Details

Frequently Asked Questions about DCM-5533

What size is the Sterlco M2B9026-J1 (DCM-5533)?

The Sterlco M2B9026-J1 is 96 kw (48 kw per zone).

What controls does DCM-5533 have?

It has Sterling M2B Controller controls.

What are the motor and power details?
  • Main Heater Power Zone #1: 48 KW (48 KW)
  • Pump Motor Size Zone #1: 3 HP (2.25 kw)
  • Main Heater Power Zone #2: 48 KW (48 KW)
  • Pump Motor Size Zone #2: 3 HP (2.25 kw)
  • Power: 126 Amps @ 460/3/60 (126 Amps @ 460/3/60)
How big and heavy is it for rigging and shipping?
  • Overall Size (L x W x H): 41 x 20 x 47 inches (1041 x 508 x 1193 mm)
  • Approximate Shipping Weight: 2,000 lbs (909 kg)
What features and accessories come with DCM-5533?
  • Sterling Hot Oil Process Heater Temperature Control Unit with Sterlco M2B Controllers
  • Alarms for low fluid pressure, pump rotation, over temperature
  • Set points for Process, High Alarm, Low Alarm
  • Displays for Process Temperature, Return Temperature and Temperature Difference
Is there a video of this machine?

Yes. Use the Play Video button beside the photos.

Is there a printable spec sheet?

Yes. Use the Print PDF button beside the photos for a printable spec sheet of DCM-5533.

Can I inspect the machine before buying?

Yes. Buyers should take the opportunity to inspect the items before purchase.

Is DCM-5533 still available?

No, DCM-5533 has been sold. See the available Hot Oil Units, or call (847) 360-9170 and mention DCM-5533.

Available Hot Oil Units