Used Sterlco Model: S9026-H1 24 KW (12 kw per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit
1 / 50Questions? Call (847) 360-9170 and mention DCM-5658.
| Status | Sold |
|---|---|
| Manufacturer | Sterlco |
| Model | S9026-H1 |
| Size | 24 KW (12 kw per zone) |
| Inventory Number | DCM-5658 |
Sterlco - S9026-H1 24 KW (12 kw per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit, Sterlco S-3 Controls
Features & Accessories
- Call us on our Hot Oil Temperature Control Unit Hot Line 7:00 AM to 7:00 PM at 1-847-360-9170 Extension 2
- Sterlco S-3 Control System
- Set points for Process, High Alarm, Low Alarm
- Displays for Process Temperature, Return Temperature and Temperature Difference
- External Expansion Tanks & Alarms for low fluid pressure, pump rotation, over temperature
- Water Cooling Circuit and Built-in pump pressure relief valve
- Unit on casters for easy movement
Item Specifications for DCM-5658
| US | Metric | |
| TOTAL KW: | 24 kW | 24 kW |
| Main Heater Power (Zone 1 & 2): | 12 kw | 12 kw |
| Pump Motor Size (Zone 1 & 2): | 1 HP | 0.75 kW |
| Flow Rate (Zone 1 & 2): | 24 gallons per minute | 90.8 liters per minute |
| Connection size/type (Zone 1 & 2): | 1 inch NPT | 1 inch NPT (25.4 mm) |
| Maximum Operating Temperature: | 400 F | 204.44 C |
| Overall Size (L x W x H): | 40 x 42 x 56 inches | 1016 x 1066.8 x 1422.4 mm |
| Full Load Amps @ 480/3/60: | 32 amp | 32 amp |
| Motor: | 1725 RPM | 1725 RPM |
Video
Documents
- Sterlco 9016 & 9026 Installation ManualPDF · 1.1 MB
- Sterlco_Schematic_Drawing_D682.82001PDF · 211 KB
Description
Used, Sterlco Model S9026-H1 24 KW (12 kw per zone) Dual (two) Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit For Sale, Features include: Sterlco S-3 Control System, Set points for Process, High Alarm, Low Alarm, Displays for Process Temperature, Return Temperature and Temperature Difference, External Expansion Tanks & Alarms for low fluid pressure, pump rotation, over temperature, Water Cooling Circuit and Built-in pump pressure relief valve, Unit on casters for easy movement, Sterlco S-3 Controls, Second Hand, DCM-5658
PURCHASER'S (Buyer's) RESPONSIBILITY AND INDEMNITY: Used machines, equipment or any part thereof, may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It shall be a Purchaser's (Buyer's) responsibility to ensure that any and all merchandise or equipment purchased from Die Cast Machinery, LLC or its affiliates is installed and operated in a proper and safe manner. Purchaser (Buyer) also acknowledges that it may have to install or change guards, safeties, warnings or other components to ensure that the merchandise or machines purchased will conform to all laws, codes, regulations, ordinances, statutes, insurance requirements and industry standards. Purchaser agrees to defend, indemnify and hold harmless Die Cast Machinery, LLC from and against all suits, claims, costs, damages and expenses, including, but not limited to, reasonable attorneys' fees, arising out of, or in connection with, the transportation, purchase, ownership, or use of the merchandise or equipment sold hereunder. Information has been obtained from sources deemed reliable, buyers should avail themselves of the opportunity to inspect the items before purchase.
Compare DCM-5658 with Similar Machines
| DCM-5658 (this machine) | DCM-6314 | DCM-5611 | DCM-5584 | |
|---|---|---|---|---|
| Brand | Sterlco | Mokon | Mokon | Sterlco |
| Model | S9026-H1 | H44212-28 | XA4G12-JZ | F6026-D-X |
| Size | 24 KW (12 kw per zone) | 24 kW (12 kW per zone) | 24 kW (12 kW per zone) | 24 kw (12 kw per zone) |
| Controls | Sterlco S-3 | — | Zytran | Sterlco Series 400 Analog |
| TOTAL KW | 24 kW | — | 24 kW | — |
| Main Heater Power (Zone 1 & 2) | 12 kw | — | 12 kW | 12 kw |
| Pump Motor Size (Zone 1 & 2) | 1 HP | — | 3 HP @ 1,730 RPM | .75 HP |
| Flow Rate (Zone 1 & 2) | 24 gallons per minute | — | — | 24 gallons per minute |
| Connection size/type (Zone 1 & 2) | 1 inch NPT | — | — | 1 inch |
| Maximum Operating Temperature | 400 F | 500 degrees F | — | 550 F |
| View Details | View Details | View Details |
Frequently Asked Questions about DCM-5658
What size is the Sterlco S9026-H1 (DCM-5658)?
The Sterlco S9026-H1 is 24 KW (12 kw per zone).
What controls does DCM-5658 have?
It has Sterlco S-3 controls.
What are the motor and power details?
- TOTAL KW: 24 kW (24 kW)
- Main Heater Power (Zone 1 & 2): 12 kw (12 kw)
- Pump Motor Size (Zone 1 & 2): 1 HP (0.75 kW)
- Motor: 1725 RPM (1725 RPM)
How big and heavy is it for rigging and shipping?
- Overall Size (L x W x H): 40 x 42 x 56 inches (1016 x 1066.8 x 1422.4 mm)
What features and accessories come with DCM-5658?
- Sterlco S-3 Control System
- Set points for Process, High Alarm, Low Alarm
- Displays for Process Temperature, Return Temperature and Temperature Difference
- External Expansion Tanks & Alarms for low fluid pressure, pump rotation, over temperature
- Water Cooling Circuit and Built-in pump pressure relief valve
- Unit on casters for easy movement
Is there a video of this machine?
Yes. Use the Play Video button beside the photos.
Is there a printable spec sheet?
Yes. Use the Print PDF button beside the photos for a printable spec sheet of DCM-5658.
Can I inspect the machine before buying?
Yes. Buyers should take the opportunity to inspect the items before purchase.
Is DCM-5658 still available?
No, DCM-5658 has been sold. See the available Hot Oil Units, or call (847) 360-9170 and mention DCM-5658.