Used Thermal Care Model: RO 242004 24 kW Single Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit
1 / 40Questions? Call (847) 360-9170 and mention DCM-5694.
| Status | Sold |
|---|---|
| Manufacturer | Thermal Care |
| Model | RO 242004 |
| Size | 24 kW |
| Inventory Number | DCM-5694 |
Thermal Care - RO 242004 24 kW Single Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit, Oiltherm RO series Digital Controls
Features & Accessories
- Call us on our Hot Oil Temperature Control Unit Hot Line 7:00 AM to 7:00 PM at 1-847-360-9170 Extension 2
- Auxiliary Water Cooling Circuit
- Oiltherm RO series Digital controls
- Low Profile Portable unit
- Same day shipping available
- Unit on casters for easy movement
Item Specifications for DCM-5694
| US | Metric | |
| Main Heater Power (Zone #1): | 24 KW | 24 KW |
| Pump Motor Size (Zone #1): | 2 HP | 1.5 KW |
| Flow Rate (Zone #1): | 14 gallons per minute | 53 liters per minute |
| Connection size/type: | 1 inch NPT | 1 inch NPT |
| Maximum Operating Temperature: | 575 degrees F | 301 degrees C |
| Catalog Overall Size (L x W x H): | 34 x 20 x 36 inches | 864 x 508 x 914 mm |
| Full Load Amps @ 460/3/60: | 31.3 AMPS | 31.3 AMPS |
| Catalog Approximate Shipping Weight: | 305 pounds | 138 kg |
Video
Documents
- RO Series ManualPDF · 1.3 MB
Description
Used, Thermal Care Model RO 242004 24 kW Single Zone Portable Hot Oil Process Heater Temperature Control Unit with Cooling Water Circuit For Sale, Features include: Auxiliary Water Cooling Circuit, Oiltherm RO series Digital controls, Low Profile Portable unit, Same day shipping available, Unit on casters for easy movement, Oiltherm RO series Digital Controls, Second Hand, DCM-5694
PURCHASER'S (Buyer's) RESPONSIBILITY AND INDEMNITY: Used machines, equipment or any part thereof, may not incorporate approved activating mechanisms, operator safety devices or safety guards as required by OSHA or otherwise. It shall be a Purchaser's (Buyer's) responsibility to ensure that any and all merchandise or equipment purchased from Die Cast Machinery, LLC or its affiliates is installed and operated in a proper and safe manner. Purchaser (Buyer) also acknowledges that it may have to install or change guards, safeties, warnings or other components to ensure that the merchandise or machines purchased will conform to all laws, codes, regulations, ordinances, statutes, insurance requirements and industry standards. Purchaser agrees to defend, indemnify and hold harmless Die Cast Machinery, LLC from and against all suits, claims, costs, damages and expenses, including, but not limited to, reasonable attorneys' fees, arising out of, or in connection with, the transportation, purchase, ownership, or use of the merchandise or equipment sold hereunder. Information has been obtained from sources deemed reliable, buyers should avail themselves of the opportunity to inspect the items before purchase.
Compare DCM-5694 with Similar Machines
| DCM-5694 (this machine) | DCM-5616 | DCM-5890 | DCM-5660 | |
|---|---|---|---|---|
| Brand | Thermal Care | Budzar Industries | Delta T Systems | Sterlco |
| Model | RO 242004 | 10T-2420-GOLSP | T1221MS | G9016-J1 |
| Size | 24 kW | 24 KW | 12 KW | 36 (18,18) kW |
| Controls | Oiltherm RO series Digital | Partlow 1160+ | Omron E5EN | West 4100 |
| Main Heater Power (Zone #1) | 24 KW | — | 12 KW | — |
| Pump Motor Size (Zone #1) | 2 HP | — | 1 HP | — |
| Flow Rate (Zone #1) | 14 gallons per minute | — | 10 Gallong Per Minute (GPM) | — |
| Connection size/type | 1 inch NPT | ? inch ANSI R.F. | 1 inch NPT | 3/4 inch NPT |
| Maximum Operating Temperature | 575 degrees F | 450 Fahrenheit | 550 degrees F | 550 degrees F |
| Full Load Amps @ 460/3/60 | 31.3 AMPS | 37 AMPS | — | — |
| View Details | View Details | View Details |
Frequently Asked Questions about DCM-5694
What size is the Thermal Care RO 242004 (DCM-5694)?
The Thermal Care RO 242004 is 24 kW.
What controls does DCM-5694 have?
It has Oiltherm RO series Digital controls.
What are the motor and power details?
- Main Heater Power (Zone #1): 24 KW (24 KW)
- Pump Motor Size (Zone #1): 2 HP (1.5 KW)
How big and heavy is it for rigging and shipping?
- Catalog Overall Size (L x W x H): 34 x 20 x 36 inches (864 x 508 x 914 mm)
- Catalog Approximate Shipping Weight: 305 pounds (138 kg)
What features and accessories come with DCM-5694?
- Auxiliary Water Cooling Circuit
- Oiltherm RO series Digital controls
- Low Profile Portable unit
- Same day shipping available
- Unit on casters for easy movement
Is there a video of this machine?
Yes. Use the Play Video button beside the photos.
Is there a printable spec sheet?
Yes. Use the Print PDF button beside the photos for a printable spec sheet of DCM-5694.
Can I inspect the machine before buying?
Yes. Buyers should take the opportunity to inspect the items before purchase.
Is DCM-5694 still available?
No, DCM-5694 has been sold. See the available Hot Oil Units, or call (847) 360-9170 and mention DCM-5694.